The RELIEVA SPINPLUS® Balloon Sinuplasty System is intended to: provide a means to access the sinus space and illuminate within and transilluminate across nasal and sinus structures; dilate the sinus ostia and spaces associated with the paranasal sinus c***ities for diagnostic and therapeutic procedures; and irrigate from within a target sinus for therapeutic procedures and to facilitate diagnostic procedures.

For children aged 17 and under, the RELIEVA SPINPLUS® Balloon Sinuplasty System is intended to: provide a means to access the sinus space and illuminate within and transilluminate across nasal and sinus structures; dilate sinus ostia and spaces associated with the maxillary sinus for diagnostic and therapeutic procedures; and irrigate from within the maxillary sinus for therapeutic procedures and to facilitate diagnostic procedures.

CONTRAINDICATI***

None.

WARNINGS

Intended for single patient use only. DO NOT REUSE.
Do not use a RELIEVA SPINPLUS® Balloon Sinuplasty System if the integrity of the sterile packaging has been compromised or if the device appears damaged.
Do not use a RELIEVA SPINPLUS® Balloon Sinuplasty System if the device becomes damaged or touches a non-sterile object outside of the operating field.
Never advance or retract the RELIEVA® Spin Sinus Guide Catheter Tip, Sinus Balloon Catheter or Sinus Illumination System against unknown resistance, as this could cause tissue trauma or device damage.
Do not try to move the Sinus Guide Catheter Tip or Sinus Balloon Catheter while the Sinus Balloon is inflated, as this could cause tissue trauma or device damage.
Do not exceed the recommended maximum Sinus Balloon inflation pressure of 12 atmospheres.
Use only sterile saline or sterile water for inflation. Do not inflate with air or radiopaque contrast.
Prior to irrigation through the RELIEVA SPINPLUS® Balloon Sinuplasty System, ensure that the balloon is fully deflated so that sinus contents and irrigation fluid can exit the sinus c***ity.
To prevent inadvertent fluid extr***asation, such as into the orbit, do not irrigate in the presence of a bony dehiscence or defect in any sinus wall.
Do not use the RELIEVA SPINPLUS® Balloon Sinuplasty System without a Sinus Guide Catheter Tip attached.
Do not insert or inflate the Sinus Balloon with the protective red-tipped Balloon Sheath in place.
Ensure the Sinus Balloon has fully exited the guide tip before inflating.
Use of a Sinus Balloon Catheter that is too large for the target sinus may cause damage to the Sinus Balloon and / or surrounding anatomy. Use of an undersized Sinus Balloon may result in failure to properly treat the target sinus.
The Balloon Sinuplasty System has a suction function that is designed to remove non-viscous fluids from the surgical field such as blood. Ensure that the suction level is reduced to the lowest level required to remove non-viscous fluids from the field. Excessively high suction levels may cause mucosal trauma.
PRECAUTI***

The RELIEVA SPINPLUS® Balloon Sinuplasty System has a suction function that is designed to remove non-viscous fluids from the surgical field such as blood. Attempting to remove viscous material from the surgical field, such as thick mucus, could lead to device clogging.
Prior to connection with an ACCLARENT® Balloon Inflation Device to the Sinus Balloon Catheter, any proximally connected tubing must be free of air or the efficiency of inflation/deflation may be compromised.
Only move or withdraw the Sinus Balloon Catheter when the Sinus Balloon is completely deflated. Advancing or retracting the Sinus Balloon Catheter while the Sinus Balloon is inflated may cause damage to the RELIEVA SPINPLUS® Balloon Sinuplasty System.
Due to the variability of sinus development in pediatric patients and as is standard practice for endoscopic sinus surgery, appropriate radiographic imaging (e.g. CT scan) should be reviewed prior to surgery to assess the development of sinus anatomy and compatibility with the Sinus Balloon Catheter.
As with any sinus surgery, the Balloon Sinuplasty System should only be used for treatment of pediatric patients who are not resp***ive to medical therapy. 
The safety of Ethylene Oxide residuals has been established in patients weighing 10 kg and above.
Before opening the sterile package, visually inspect the package to ensure that the seals remain intact, the sterile integrity has not been compromised, and no damage has occurred during shipping and handling.
Do not use the Sinus Illumination System with light sources whose bulbs are less than 20 hours old. Device damage may occur.
Do not pinch or kink the wire, as this may result in reduction or loss of transcutaneous illumination.
Do not attempt to alter the distal tip of the wire, as this may result in device damage.
If using the system to trans-illuminate the frontal sinus, pre-operative review of a CT, x-ray or other image is recommended to help facilitate identification of the frontal sinus.
Use only RELIEVA LUMA® Light Guide Cables.with the RELIEVA SPINPLUS® Balloon Sinuplasty System, as standard light guide cables may damage the optical components.
Light from the tip of the system may transcutaneously illuminate tissue structures. The location and intensity of the transcutaneous illumination will depend on the sinus entered, orientation of the wire, and patient characteristics.
To ensure maximum light tran***ission for subsequent uses in the same patient, rinse the distal tip of the Sinus Illumination System in saline after use in each sinus. 

免责声明
• 本文仅代表作者个人观点,本站未对其内容进行核实,请读者仅做参考,如若文中涉及有违公德、触犯法律的内容,一经发现,立即删除,作者需自行承担相应责任。涉及到版权或其他问题,请及时联系我们 304108043@qq.com
  • 张宝先生 QQ在线咨询84123995
  • 手机:18901717898
  • 联系我时务必告知是在产品网上看到的!

沛显传动系统(上海)有限公司

商铺|诚信档案

地址:上海市金山区亭林镇林珍路58弄128号

电话:18901717898传真:021-67228996

免责声明:以上信息由会员自行提供,内容的真实性、准确性和合法性由发布会员负责,产品网对此不承担任何责任。产品网不涉及用户间因交易而产生的法律关系及法律纠纷, 纠纷由您自行协商解决。

风险提醒:本网站仅作为用户寻找交易对象,就货物和服务的交易进行协商,以及获取各类与贸易相关的服务信息的平台。为避免产生购买风险,建议您在购买相关产品前务必 确认供应商资质及产品质量。过低的价格、夸张的描述、私人银行账户等都有可能是虚假信息,请采购商谨慎对待,谨防欺诈,对于任何付款行为请您慎重抉择!如您遇到欺诈 等不诚信行为,请您立即与产品网联系,如查证属实,产品网会对该企业商铺做注销处理,但产品网不对您因此造成的损失承担责任!

联系:304108043@qq.com是处理侵权投诉的专用邮箱,在您的合法权益受到侵害时,欢迎您向该邮箱发送邮件,我们会在3个工作日内给您答复,感谢您对我们的关注与支持!

商铺首页 | 公司概况 | 供应信息 | 新闻动态 | 诚信档案 | 联系我们 |

沛显传动系统(上海)有限公司 电话:021-67228996 传真:021-67228996 联系人:张宝 18901717898

地址:上海市金山区亭林镇林珍路58弄128号 主营产品:FENLIBELT工业皮带,MEGADYNE同步带,MEGADYNE三角带

Copyright © 2024 版权所有: 产品网

免责声明:以上所展示的信息由企业自行提供,内容的真实性、准确性和合法性由发布企业负责。产品网对此不承担任何保证责任。

商盟客服

您好,欢迎莅临沛显传动,欢迎咨询...

QQ在线咨询
QQ在线咨询
18901717898